Snapshot Spec Cards
Core Platform
HH-2000
Flow Range
100-600 GPM
Head Range
Up to 350 ft
Solids Handling
Up to 1.75 in
% Solids
40-70%
Production
25-60 (yd³/hr)
Discharge / Suction
2 in / 3 in
Max Pump Speed
2,250 RPM
The HH-2000 is the high-head 2-inch EDDY Pump platform for slurry applications that need compact solids handling plus higher head capability. With 100–600 GPM, head up to 350 ft, solids handling up to 1.75 in, and 40–70% solids by weight capability, it is best used when the standard HD-2000 does not provide enough head for the discharge distance, elevation change, or system resistance.
Why Choose the HH-2000?
Choose the HH-2000 when the project needs the size and solids handling of a 2-inch slurry pump, but the duty point requires significantly higher head than the standard HD-2000 platform. This makes it a strong fit for longer discharge lines, vertical lift, restrictive piping systems, cyclone feed support, dense slurry transfer, and compact high-pressure slurry service.
Built around the EDDY Pump patented non-clog slurry pump design.
Designed for abrasive, dense, and solids-laden slurry service.
Flexible configuration options for plant, field, dredging, and engineered system applications.
Strong fit when the customer needs to match the pump platform, power package, and deployment method to the actual duty point.
Available HH-2000 Configurations
Electric Direct Drive
Best for fixed installations
and plant process applications with reliable site power.
Electric Self-Priming
Best for surface installations where electric power is available and the pump must pull from below grade.
Diesel Self-Priming
Best for remote jobsites, mobile pumping, and field locations without dependable electric power.
Best-Fit Applications
This platform is the right choice when head pressure matters as much as solids handling. It gives customers a compact high-solids slurry pump option for applications where a larger pump may not be necessary, but a standard 2-inch pump may not carry the duty point.
High-head slurry transfer
Longer discharge lines
Vertical lift applications
Mine tailings and underflow
Cyclone feed and process slurry
Drilling mud and cuttings
Fly ash and bottom ash slurry
Industrial sludge and grit transfer
Dredging support in compact systems
Pump Platform Specifications
| Spec | Value |
|---|---|
| Pump Model | HH-2000 |
| Discharge Size | 2 in |
| Suction Size | 3 in |
| Flow Range (GPM) | 100–600 |
| Head Range (ft) | Up to 350 |
| Solids Handling | Up to 1.75 in |
| % Solids by Weight | 40–70% |
| Production Rate (yd³/hr) | 25–60 |
| Max Pump Speed (RPM) | 2,250 |
| Spec Sheet | Download |
Selection note: Final pump selection should be based on the full duty point, including slurry density, total dynamic head, discharge distance, pipe size, elevation change, solids size, abrasiveness, available power source, and duty cycle.
Compare All EDDY Pump Slurry Pump Platforms Specifications
| Pump Platform | Discharge Size | Suction Size | Flow Range (GPM) | Head Range (ft) | Solids Handling | % Solids by Weight | Production Rate (yd³/hr) | Max Pump Speed (RPM) | Spec Sheet |
|---|---|---|---|---|---|---|---|---|---|
| HD-1000 | 1 in | 1.5 in | 1–200 | Up to 170 | Up to 0.75 in | 40–70% | 0–15 | 1,800–3,600 | Download |
| HD-2000 | 2 in | 3 in | 50–390 | Up to 90 | Up to 1.75 in | 40–70% | 15–45 | 1,800 | Download |
| CURRENT PAGE – HH-2000 | 2 in | 3 in | 100–600 | Up to 350 | Up to 1.75 in | 40–70% | 25–60 | 2,250 | Download |
| HD-3000 | 3 in | 4 in | 100–780 | Up to 130 | Up to 2 in | 40–70% | 45–75 | 1,800 | Download |
| HD-4000 | 4 in | 6 in | 250–1,200 | Up to 160 | Up to 3 in | 40–70% | 75–150 | 1,800 | Download |
| HD-5000 5×5 | 5 in | 5 in | 400–1,800 | Up to 225 | Up to 4 in | 40–70% | 100–175 | 1,800 | Download |
| HD-5000 6×5 | 5 in | 6 in | 400–1,800 | Up to 225 | Up to 4 in | 40–70% | 100–175 | 1,800 | Download |
| HD-6000 | 6 in | 8 in | 450–2,500 | Up to 200 | Up to 5 in | 40–70% | 150–200 | 1,800 | Download |
| HD-8000 | 8 in | 10 in | 1,400–3,600 | Up to 230 | Up to 7 in | 40–70% | 250–300 | 1,200 | Download |
| HD-10000 | 10 in | 12 in | 1,600–5,000 | Up to 240 | Up to 9 in | 40–70% | 300–350 | 1,200 | Download |
| HD-12000 | 12 in | 14 in | 2,600–7,300 | Up to 180 | Up to 11 in | 40–70% | 500–600 | 900 | Download |
| HD-16000 | 16 in | 18 in | 10,000–13,000 | Up to 180 | Up to 15 in | 40–70% | 700–1,000 | 700 | Download |
Driver / Power Package Options
| Package / Spec Item | Value | Best-Fit Use |
|---|---|---|
| Standard Wet-End Construction | High Chrome | Use this material language in the specs table and material card. |
| Electric Direct-Drive Motor HP Options | 30 HP, 40 HP, 50 HP, 60 HP | Best for fixed plant, mill, process, and industrial systems with reliable electric power. |
| Submersible Electric Motor HP Options | 30 HP, 40 HP, 50 HP, 60 HP | Best when the pump needs to sit directly in the slurry source. |
| Electric Self-Priming Motor HP Options | 30 HP, 40 HP, 50 HP, 60 HP | Best for surface-mounted installations where electric power is available but suction lift or remote placement matters. |
| Diesel Self-Priming Engine HP Options | 43 HP | Best for remote jobsites, rentals, dredging support, emergency response, and field pumping. |
| Hydraulic / HPU-Powered Options | Application dependent | Best for excavator attachments, cable-deployed pumps, diver-operated pumps, dredging systems, and HPU-powered packages. |
Same EDDY Pump Platform, Multiple Configurations
The HH-2000 pump platform can be configured for multiple slurry pumping applications depending on the jobsite, power source, installation method, and material being pumped. Start with the core pump size, then choose the configuration that fits how the slurry will be collected, moved, and discharged.
| Configuration | Best Fit | When to Choose This Configuration | Link |
|---|---|---|---|
| Flooded Suction Slurry Pump |
Fixed plant, process, tank, pit, and sump applications where the pump is installed below liquid level and gravity helps feed the suction side. |
Use when the slurry source can gravity-feed the pump and the customer wants a surface-mounted installation. |
View Flooded Suction Pumps → |
| Submersible Slurry Pump | Pits, ponds, lagoons, tanks, basins, and applications where the pump operates directly in the slurry source. |
Use when suction lift is a problem or when the pump needs to sit close to settled solids. |
View Submersible Slurry Pumps → |
| Electric Self-Priming Slurry Pump |
Surface-mounted applications where electric power is available but the pump must sit above or away from the slurry source. |
Use when the customer wants surface access, clean electric power, and self-prime capability. |
View Self-Priming Pumps → |
| Diesel Self-Priming Slurry Pump | Remote jobsites, dredging support, construction, bypass, emergency pumping, and mobile field applications where grid power is unavailable. |
Use when mobility and a self-contained field package matter. |
View Diesel Self-Priming Pumps → |
| Hydraulic / HPU-Powered Slurry Pump |
Excavator attachments, cable-deployed pumps, diver-operated pumps, dredging systems, and hydraulic power unit applications. |
Use when the pump is driven by an excavator, hydraulic power unit, cutterhead system, auger system, or specialty dredging package. |
View Excavator Pump Attachments → |
| Booster / Pipeline Support |
Long discharge lines, elevation changes, high friction losses, or large pipeline transfer projects. |
Use when one pump cannot maintain the required flow and head across the full discharge line. |
View Booster Pumps → |
| Dredging and Solids Removal Systems |
Pond, lagoon, mine tailings, sediment, sludge, and industrial cleanout projects where the pump is integrated into a dredging system. |
Use when the buyer is solving a material-removal problem, not just buying a standalone pump. |
View Autonomous ModDredge → |
Not sure which configuration fits your slurry application? EDDY Pump can help match the 2-Inch High Head Slurry Pump platform, driver package, power source, and deployment method to your flow, head, solids size, discharge distance, and production target.
Inside the EDDY Pump Difference
The inside of the HH-2000 is the core differentiator. EDDY Pump uses a patented recessed rotor and open internal flow path to help keep solids moving and reduce clogging in heavy slurry service.
Large open internal flow path for abrasive solids.
Patented recessed rotor design that helps reduce direct rotor contact with oversized solids.
High-solids slurry movement with less dependence on dilution water.
Strong fit for abrasive, dense, viscous, and solids-laden slurry service.
Standard High Chrome wet-end construction with custom material options by application.
Common Fluids Pumped
Sludge
Grit
Sand slurry
Tailings
Drilling mud
Fly ash slurry
Sediment
Process slurry
Industrial wastewater solids
Materials and Construction
- Standard Wet-End Construction: High Chrome. Other materials and custom metals are available by application.
- Rotor and volute options may include High Chrome 28%, ductile iron, stainless steel, and duplex stainless, depending on application and configuration.
- Application-specific material upgrades may include stainless or duplex stainless options when corrosive, seawater, chemical, low-pH, or extreme-abrasion conditions require it.
Frequently Asked Questions
What is the 2-Inch High Head Slurry Pump best used for?
The 2-Inch High Head Slurry Pump is best used for compact high-solids applications that require higher head pressure, longer discharge runs, vertical lift, or restrictive piping where the standard 2-inch slurry pump may not meet the duty point.
What is the difference between the HH-2000 and the HD-2000?
Both are 2-inch discharge slurry pump platforms with 3-inch suction sizing and up to 1.75-inch solids handling. The HH-2000 is the high-head option, with 100–600 GPM and up to 350 ft of head, while the HD-2000 is a standard 2-inch platform for lower-head duty points.
Can the 2-Inch High Head Slurry Pump handle high-solids slurry?
Yes. The 2-Inch High Head Slurry Pump platform is designed for high-solids slurry service and is commonly specified around 40–70% solids by weight, application dependent.
What configurations are available for the 2-Inch High Head Slurry Pump?
Depending on the final duty point and application review, the platform may be configured as electric direct-drive, submersible electric, electric self-priming, diesel self-priming, hydraulic / HPU-powered, booster-supported, or integrated into a dredging system.
How should the 2-Inch High Head Slurry Pump be selected?
Final selection should be based on slurry density, solids size, total dynamic head, discharge distance, pipe size, elevation change, abrasiveness, percent solids by weight, available power, and duty cycle.